Logo Repositorio Institucional

Please use this identifier to cite or link to this item: https://dspace.ucuenca.edu.ec/handle/123456789/46051
Title: Incidence of non-working days on limiting photovoltaic potential on a building with day-hours high power consumption, without storage and grid injection
Authors: Astudillo Flores, Mateo Ismael
Zalamea Leon, Esteban Felipe
Ochoa Correa, Danny Vinicio
metadata.dc.ucuenca.correspondencia: Ochoa Correa, Danny Vinicio, danny.ochoac@ucuenca.edu.ec
Keywords: Building integrated PV
Energy efficiency
PV production self-consumptions
PV matching
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.2.1 Ingeniería Eléctrica y Electrónica
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.2 Ingenierias Eléctrica, Electrónica e Información
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0713 - Electricidad y Energia
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2024
metadata.dc.ucuenca.volumen: Volumen 2
metadata.dc.source: E&Q Journal (Energies and Quality Journal)
metadata.dc.identifier.doi: 10.24084/eqj24.280
Publisher: BOARD
metadata.dc.description.city: 
Bilbao
metadata.dc.type: ARTÍCULO DE CONFERENCIA
Abstract: 
This study investigates the practicality of a 7 kWp photovoltaic (PV) system designed to partially supply power to the Faculty of Architecture and Urbanism buildings at the University of Cuenca, Ecuador, without storage or bidirectional meter. Leveraging theoretical capacity alignment with irradiation, the system aims to avoid surpluses, as it is not connected to the grid through net metering, net billing, or a storage system. Despite the equatorial location's low seasonal fluctuations and reduced irradiation and energy demand variations, significant consumption fluctuations between working and non-working days pose a primary challenge. Implementing a system with the potential to cover around 7,5% of the total annual demand, surpluses occur at midday on non-working days, reaching 2,7 kW, yet annually constituting only 0,17% of overall consumption or 2,2% of total energy production. This underscores the limitations of nonworking day fluctuations despite the system's potential for on-site energy generation during working hours.
URI: https://dspace.ucuenca.edu.ec/handle/123456789/46051
https://www.enerqj.com/E&Q2-1.html
metadata.dc.ucuenca.urifuente: https://www.enerqj.com/E&Q-papers.htm
ISBN: 978-84-09-60656-6
ISSN: 2659-8779
Appears in Collections:Artículos

Files in This Item:
File SizeFormat 
documento.pdf2.11 MBAdobe PDFView/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00