Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: https://dspace.ucuenca.edu.ec/handle/123456789/45808
Título : GIS-based assessment of photovoltaic solar potential on building rooftops in equatorial urban areas
Autor: Zalamea Leon, Esteban Felipe
Mejia Coronel, Julio Danilo
Palabras clave : Solar rooftops
LiDAR technology
Urban planning
Urban energy self-sufficiency
Área de conocimiento FRASCATI amplio: 2. Ingeniería y Tecnología
Área de conocimiento FRASCATI detallado: 2.2.1 Ingeniería Eléctrica y Electrónica
Área de conocimiento FRASCATI específico: 2.2 Ingenierias Eléctrica, Electrónica e Información
Área de conocimiento UNESCO amplio: 07 - Ingeniería, Industria y Construcción
ÁArea de conocimiento UNESCO detallado: 0713 - Electricidad y Energia
Área de conocimiento UNESCO específico: 071 - Ingeniería y Profesiones Afines
Fecha de publicación : 2025
Volumen: Volumen 11, número 1
Fuente: Heliyon
metadata.dc.identifier.doi: 10.1016/j.heliyon.2024.e41425
Tipo: ARTÍCULO
Abstract: 
Installing photovoltaic systems (PVs) on building rooftops is a viable and sustainable alternative to meet the growing demand for electricity in cities. This work develops a methodology that uses LiDAR (laser imaging detection and ranging) technology and roof footprints to obtain a three-dimensional representation of the rooftops in the urban centre of Santa Isabel (Azuay, Ecuador). This allowed the determination of characteristics such as area, slope, orientation, and received solar radiation, making it possible to calculate the rooftop's theoretical, technical, and economic photovoltaic potential. It was found that 68.8 % of the total roof surface is suitable for PV capture, with which a theoretical photovoltaic potential of 62.39 GWh can be achieved. The annual technical photovoltaic potential using silicon panels was calculated at 4.85 GWh, which could supply 4.97 times the demand of the analyzed neighbourhood. To determine the economic potential, the peak power of a solar project was calculated to match the electricity demand of the analysis area, with a levelized cost of energy of 12.37 c$/kWh. This project could prevent the emission of 6805 tons of CO₂ into the environment during its useful life. The methodology developed in this study can be replicated in other areas to determine their photovoltaic potential and contribute to the diversification and decentralization of electricity generation systems, as well as transform Ecuador's energy matrix.
URI : https://dspace.ucuenca.edu.ec/handle/123456789/45808
https://www.scopus.com/record/display.uri?eid=2-s2.0-85213002823&origin=resultslist&sort=plf-f&src=s&sot=b&sdt=b&s=TITLE-ABS-KEY%28GIS-based+assessment+of+photovoltaic+solar+potential+on+building+rooftops+in+equatorial+urban+areas%29&sessionSearchId=a9e9d8c39e5f5adfc91933a62349e8f6&relpos=0
URI Fuente: https://www.sciencedirect.com/journal/heliyon
ISSN : 24058440
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
documento.pdf6.34 MBAdobe PDFVisualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00