Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: https://dspace.ucuenca.edu.ec/handle/123456789/45769
Título : Comparative Study of the Influence of Heat Treatment on Fracture Resistance of Different Ceramic Materials Used for CAD/CAM Systems
Autor: Abad Coronel, Cristian Gustavo
Palabras clave : CAD CAM materials
Ceramics
Crystallization
Mechanical characterization
Properties
Thermal influence
Área de conocimiento FRASCATI amplio: 3. Ciencias Médicas y de la Salud
Área de conocimiento FRASCATI detallado: 3.2.15 Odontología
Área de conocimiento FRASCATI específico: 3.2 Medicina Clínica
Área de conocimiento UNESCO amplio: 09 - Salud y Bienestar
ÁArea de conocimiento UNESCO detallado: 0912 - Medicina
Área de conocimiento UNESCO específico: 091 - Salud
Fecha de publicación : 2024
Volumen: Volumen 17, número 6
Fuente: Materials
metadata.dc.identifier.doi: 10.3390/ma17061246
Tipo: ARTÍCULO
Abstract: 
The aim of this study was to compare the influence of heat treatment on fracture resistance (FR) of different ceramic materials used for CAD/CAM systems. Methods: Eighty monolithic restorations were designed using the same parameters and milled with a CAD/CAM system (CEREC SW 5.0, PrimeMill, Dentsply-Sirona™, Bensheim, Germany), forming five study groups: Group 1 (n = 10), CEREC Tessera (Dentsply-Sirona™, Bensheim, Germany) crystallized (CCT), Group 2 (n = 10), CEREC Tessera uncrystallized (UCT), Group 3 (n = 20), Emax-CAD (Ivoclar Vivadent, Schaan, Liechtenstein) (CEC), Group 4 (n = 20), Vita Suprinity (Vita Zahnfabrik, Bad Säckingen, Germany) (CVS), and Group 5 (n = 20) Cameo (Aidite, Qinhuangdao, China) (CC). Results: The average FR was similar for CCT, CC, and CEC at above 400 N, while CVS and UCT had the lowest values at 389,677 N and 343,212 N, respectively. Conclusion: Among the three ceramic materials that exhibited an FR above 400 N, CCT was considered the first recommended choice for CAD/CAM systems. This material not only demonstrated the highest FR but also exhibited outstanding consistency in the related measurements without the presence of outliers. Although the CC material showed high FR, its high dispersion revealed inconsistencies in the repetitions, suggesting caution in its use.
URI : https://www.scopus.com/inward/record.uri?eid=2-s2.0-85189102636&doi=10.3390%2fma17061246&partnerID=40&md5=c46334750b95cd62be9816bfa93f5a97
URI Fuente: https://www.mdpi.com/journal/materials
ISSN : 1996-1944
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
documento.pdf9.86 MBAdobe PDFVisualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00