Title: Comparative Study of the Influence of Heat Treatment on Fracture Resistance of Different Ceramic Materials Used for CAD/CAM Systems
Authors: Abad Coronel, Cristian Gustavo
Keywords: CAD CAM materials
Ceramics
Crystallization
Mechanical characterization
Properties
Thermal influence
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 3. Ciencias Médicas y de la Salud
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 3.2.15 Odontología
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 3.2 Medicina Clínica
metadata.dc.ucuenca.areaconocimientounescoamplio: 09 - Salud y Bienestar
metadata.dc.ucuenca.areaconocimientounescodetallado: 0912 - Medicina
metadata.dc.ucuenca.areaconocimientounescoespecifico: 091 - Salud
Issue Date: 2024
metadata.dc.ucuenca.volumen: Volumen 17, número 6
metadata.dc.source: Materials
metadata.dc.identifier.doi: 10.3390/ma17061246
metadata.dc.type: ARTÍCULO
Abstract: 
The aim of this study was to compare the influence of heat treatment on fracture resistance (FR) of different ceramic materials used for CAD/CAM systems. Methods: Eighty monolithic restorations were designed using the same parameters and milled with a CAD/CAM system (CEREC SW 5.0, PrimeMill, Dentsply-Sirona™, Bensheim, Germany), forming five study groups: Group 1 (n = 10), CEREC Tessera (Dentsply-Sirona™, Bensheim, Germany) crystallized (CCT), Group 2 (n = 10), CEREC Tessera uncrystallized (UCT), Group 3 (n = 20), Emax-CAD (Ivoclar Vivadent, Schaan, Liechtenstein) (CEC), Group 4 (n = 20), Vita Suprinity (Vita Zahnfabrik, Bad Säckingen, Germany) (CVS), and Group 5 (n = 20) Cameo (Aidite, Qinhuangdao, China) (CC). Results: The average FR was similar for CCT, CC, and CEC at above 400 N, while CVS and UCT had the lowest values at 389,677 N and 343,212 N, respectively. Conclusion: Among the three ceramic materials that exhibited an FR above 400 N, CCT was considered the first recommended choice for CAD/CAM systems. This material not only demonstrated the highest FR but also exhibited outstanding consistency in the related measurements without the presence of outliers. Although the CC material showed high FR, its high dispersion revealed inconsistencies in the repetitions, suggesting caution in its use.
URI: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85189102636&doi=10.3390%2fma17061246&partnerID=40&md5=c46334750b95cd62be9816bfa93f5a97
metadata.dc.ucuenca.urifuente: https://www.mdpi.com/journal/materials
ISSN: 1996-1944
Appears in Collections:Artículos

Files in This Item:
File SizeFormat 
documento.pdf9.86 MBAdobe PDFView/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00