dc.descriptionEn el presente trabajo se analiza la viabilidad técnica, financiera y ambiental de implementar un sistema solar térmico para el precalentamiento de agua de alimentación de la caldera para los laboratorios de la Facultad de Ciencias Químicas ubicado en la Universidad de Cuenca (Campus Balzay). Para ello, se realizaron simulaciones en los softwares f-chart, SAM y TRNSYS, con el fin de comparar un sistema de colectores de placa plana con uno de tubos de vacío. Como resultados del análisis técnico y ambiental obtenidos de la simulación se concluyó que los colectores de placa plana alcanzaron una temperatura promedio de 43.77 °C, con un ahorro de combustible del 29.47% y una reducción de emisiones de 1939.04 kgCO2Eq. Por otro lado, los tubos de vacío lograron una temperatura de 61.61 °C, con un ahorro anual de combustible del 40.45% y una reducción de emisiones de 2660.59 kgCO2Eq. Con respecto al análisis financiero, ambos sistemas resultaron no rentables al utilizar un precio subsidiado de 1.75 USD/gal; sin embargo, al considerar un precio no subsidiado (3.53 USD/gal) los colectores de tubos de vacío demostraron ser más rentables, posicionándose como la opción más adecuada.en_US
dc.description.abstractThis paper analyzes the technical, financial and environmental feasibility of implementing a solar thermal system for preheating the boiler feed water for the laboratories of the Faculty of Chemical Sciences located at the University of Cuenca (Campus Balzay). For this purpose, simulations were performed in f-chart, SAM and TRNSYS softwares, in order to compare a flat plate collector system with a evacuated tube system. As results of the technical and environmental analysis obtained from the simulation, it was concluded that the flat plate collectors reached an average temperature of 43.77 °C, with a fuel saving of 29.47% and an emission reduction of 1939.04 kgCO2Eq. On the other hand, the vacuum tubes achieved a temperature of 61.61 °C, with an annual fuel saving of 40. 45% and an emission reduction of 2660.59 kgCO2Eq. With respect to the financial analysis, both systems were not profitable when using a subsidized price of 1.75 USD/gal; however, when considering a non-subsidized price (3.53 USD/gal) the evacuated tube collectors proved to be more profitable, positioning themselves as the most appropriate option.en_US
dc.description.uri0000-0001-5366-8029en_US
dc.formatapplication/pdfen_US
dc.format.extent168 páginasen_US
dc.language.isospaen_US
dc.publisherUniversidad de Cuencaen_US
dc.relation.ispartofTQ;649-
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectIngeniería Químicaen_US
dc.subjectColectores solaresen_US
dc.subjectRentabilidaden_US
dc.subjectViabilidad ambientalen_US
dc.subject.otherClasificación de la Investigación::Químicaen_US
dc.titleDiseño y simulación de un sistema de energía solar térmica para precalentamiento de agua de caldera de los laboratorios de la Facultad de Ciencias Químicasen_US
dcterms.descriptionIngeniero Químicoen_US
dcterms.spatialCuenca, Ecuadoren_US
dc.rights.accessRightsopenAccessen_US
Aparece en las colecciones: Tesis de Pregrado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Trabajo-de-Titulación.pdfVersión presentada (texto completo)9.42 MBAdobe PDFVisualizar/Abrir


Este ítem está protegido por copyright original



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00