Logo Repositorio Institucional

Please use this identifier to cite or link to this item: https://dspace.ucuenca.edu.ec/handle/123456789/45276
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorGarcía Ávila, Fausto Fernando-
dc.contributor.authorAguilar Chuya, Evelin Andrea-
dc.contributor.authorChuñir Chillogallo, Joseph Ricardo-
dc.date.accessioned2024-09-12T03:54:36Z-
dc.date.available2024-09-12T03:54:36Z-
dc.date.issued2024-09-11-
dc.identifier.urihttps://dspace.ucuenca.edu.ec/handle/123456789/45276-
dc.descriptionEste estudio abordó el comportamiento del cloro residual en una red de distribución de agua potable. El cloro es el desinfectante más utilizado globalmente, ya que su residual libre asegura la desinfección continua del agua en la red. En áreas rurales, la deficiencia en el tratamiento del agua cruda y su desinfección requiere conocer la cinética del cloro para optimizar la desinfección y cumplir con la normativa nacional sobre la concentración de cloro residual. Los objetivos incluyeron determinar el orden de reacción y las constantes cinéticas del cloro: constante de reacción con el agua (kb) y con la pared de la tubería (kw). Se buscó mejorar la dosificación en la planta de tratamiento de agua potable (PTAP) obteniendo la dosis óptima de hipoclorito de calcio según las características del agua filtrada. En 15 puntos de muestreo estratégicos, se midió la concentración de cloro residual en verano (agosto, septiembre, octubre) e invierno (febrero, marzo, abril). Usando el método integral, se determinó el orden de reacción, y mediante ajuste exponencial, las constantes cinéticas (kb=0.406 h-1 y kw=0.079 h-1). Para optimizar la dosificación de cloro, se realizó la cloración a punto de quiebre en tres ensayos, obteniéndose una dosis óptima de 2.97 mg/L con un cloro residual de 0.92 mg/L. El estudio concluyó en que las constantes cinéticas son específicas para cada red de distribución, dependiendo del agua y el entorno. Los resultados obtenidos sobre la dosis óptima concuerdan con la literatura, validando el método aplicado.en_US
dc.description.abstractThis study addressed the behavior of residual chlorine in a drinking water distribution network. Chlorine is the most widely used disinfectant globally, since its free residual ensures the continuous disinfection of water in the network. In rural areas, the deficiency in the treatment of raw water and its disinfection requires knowing the kinetics of chlorine to optimize disinfection and comply with national regulations on residual chlorine concentration. The objectives included determining the order of reaction and the kinetic constants of chlorine: constant of reaction with water (kb) and with the pipe wall (kw). It was sought to improve the dosage in the drinking water treatment plant (PTAP) obtaining the optimal dose of calcium hypochlorite according to the characteristics of the filtered water. At 15 strategic sampling points, the concentration of residual chlorine was measured in summer (August, September, October) and winter (February, March, April). Using the integral method, the order of reaction was determined, and by exponential adjustment, the kinetic constants (kb=0.406 h-1 and kw=0.079 h-1 ). To optimize the chlorine dosage, point-of-break chlorination was carried out in three trials, obtaining an optimal dose of 2.97 mg/L with a residual chlorine of 0.92 mg/L. The study concluded that the kinetic constants are specific to each distribution network, depending on the water and the environment. The results obtained on the optimal dose are consistent with the literature, validating the method applied.en_US
dc.description.uri0000-0002-9274-9769en_US
dc.formatapplication/pdfen_US
dc.format.extent120 páginasen_US
dc.language.isospaen_US
dc.publisherUniversidad de Cuencaen_US
dc.relation.ispartofTIA;259-
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectIngeniería Ambientalen_US
dc.subjectCloro residualen_US
dc.subjectConstantes cinéticasen_US
dc.subjectDosis óptimaen_US
dc.subject.otherClasificación de la Investigación::Ingeniería Ambiental::Microbiología Ambientalen_US
dc.titleComportamiento cinético del cloro libre y optimización de la dosificación de cloro en el sistema de agua potable de Tutupali Chicoen_US
dc.typebachelorThesisen_US
dcterms.descriptionIngeniero Ambientalen_US
dcterms.spatialCuenca, Ecuadoren_US
dc.rights.accessRightsopenAccessen_US
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
Trabajo-de-Titulación.pdfVersión presentada (texto completo)7.75 MBAdobe PDFView/Open


This item is protected by original copyright



This item is licensed under a Creative Commons License Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00