Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: https://dspace.ucuenca.edu.ec/handle/123456789/44251
Título : Comparative Analysis of the Structural Weights of Fixed Prostheses of Zirconium Dioxide, Metal Ceramic, PMMA and 3DPP Printing Resin—Mechanical Implications
Autor: Lupu Flores, Billy Darlin
Pacurucu Mendieta, Miguel David
Velez Chimbo, David Alejandro
Abad Coronel, Cristian Gustavo
Correspondencia: Abad Coronel, Cristian Gustavo, cristian.abad@ucuenca.edu.ec
Palabras clave : 3D FEA
Zirconium dioxide
Structural weight
PMMA
Metal ceramic
Mechanical implications
Fixed prosthesis
CAD CAM materials
3D printed
Área de conocimiento FRASCATI amplio: 3. Ciencias Médicas y de la Salud
Área de conocimiento FRASCATI detallado: 3.2.15 Odontología
Área de conocimiento FRASCATI específico: 3.2 Medicina Clínica
Área de conocimiento UNESCO amplio: 09 - Salud y Bienestar
ÁArea de conocimiento UNESCO detallado: 0911 - Estudios Dentales
Área de conocimiento UNESCO específico: 091 - Salud
Fecha de publicación : 2023
Volumen: Volumen 11 número 11
Fuente: Dentistry Journal
metadata.dc.identifier.doi: 10.3390/dj11110249
Tipo: ARTÍCULO
Abstract: 
The aim of this study was to determine the mechanical implications of four-unit fixed dental prostheses (FDPs) made of (1) monolithic zirconium dioxide (ZR O2), (2) polymethylmethacrylate (PMMA), (3) metal ceramic (PFM) and (4) impression resin (3DPP). Methods: Four groups were studied with eight samples for each material (n: 32). Each structure was weighed, subjected to compressive tests and analyzed using 3D FEA. Results: PMMA presented the lowest structural weight (1.33 g), followed by 3DPP (1.98 g), ZR O2 (6.34 g) and PFM (6.44 g). In fracture tests, PMMA presented a compressive strength of 2104.73 N and a tension of 351.752 MPa; followed by PFM, with a strength of 1361.48 N and a tension of 227.521 MPa; ZR O2, with a strength of 1107.63 N and a tension of 185.098 MPa; and 3DPP, with a strength of 1000.88 N and a tension of 143.916 MPa. According to 3D FEA, 3DPP presented the lowest degree of deformation (0.001 mm), followed by PFM (0.011 mm), ZR O2 (0.168 mm) and PMMA (1.035 mm). Conclusions: The weights of the materials did not have a direct influence on the mean values obtained for strength, stress or strain. Since the performance was related to the tension and forces supported by the structures in critical zones, the importance of considering design factors is clear. In vitro and 3D FEA assays allowed us to simulate different scenarios for the mechanical properties of certain materials before evaluating them clinically. Thus, they can generate predictions that would allow for the design of a better research methodology in future clinical trials.
URI : http://dspace.ucuenca.edu.ec/handle/123456789/44251
https://www.scopus.com/record/display.uri?eid=2-s2.0-85178086034&origin=resultslist&sort=plf-f&src=s&sid=44c9f233713703853d929a946faddeae&sot=b&sdt=b&s=TITLE-ABS-KEY%28Comparative+Analysis+of+the+Structural+Weights+of+Fixed+Prostheses+of+Zirconium+Dioxide%2C+Metal+Ceramic%2C+PMMA+and+3DPP+Printing+Resin%E2%80%94Mechanical+Implications%29&sl=171&sessionSearchId=44c9f233713703853d929a946faddeae&relpos=0
URI Fuente: https://www.mdpi.com/journal/dentistry
ISSN : 2304-6767
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
documento.pdf3.16 MBAdobe PDFVisualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00