Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: https://dspace.ucuenca.edu.ec/handle/123456789/44114
Título : A Low-Cost IoT Architecture Based on LPWAN and MQTT for Monitoring Water Resources in Andean Wetland
Autor: Gonzalez Armijos, Luis Eduardo
Gonzalez Martinez, Santiago Renan
Gonzales Zapata, Andres Amauta
Correspondencia: Gonzalez Martinez, Santiago Renan, santiago.gonzalezm@ucuenca.edu.ec
Palabras clave : Water sources
Hydrology
Monitoring system
Andean wetlands
Área de conocimiento FRASCATI amplio: 2. Ingeniería y Tecnología
Área de conocimiento FRASCATI detallado: 2.10.2 Nano-Procesos [Aplicaciones a Nano-Escala]
Área de conocimiento FRASCATI específico: 2.10 NanoTecnología
Área de conocimiento UNESCO amplio: 07 - Ingeniería, Industria y Construcción
ÁArea de conocimiento UNESCO detallado: 0714 - Electrónica y Automatización
Área de conocimiento UNESCO específico: 071 - Ingeniería y Profesiones Afines
Fecha de publicación : 2024
Fecha de fin de embargo: 30-dic-2050
Volumen: Volumen 5, número 144
Fuente: SN Computer Science
metadata.dc.identifier.doi: 10.1007/s42979-023-02515-4
Tipo: ARTÍCULO
Abstract: 
This paper describes the development of a monitoring system for water sources in the Tres Lagunas Andean high-altitude wetlands ecosystem (Ecuador), utilizing LoRa technology. The system design primarily involves an ATmega1284p microcontroller, LoRa transceiver, and physicochemical sensors. Data collected from the study site are transmitted to the server and then forwarded to the Node-RED platform using the MQTT protocol. Additionally, a graphical user interface has been created to facilitate the analysis of the data related to temperature, dissolved oxygen (DO), oxidation–reduction potential (ORP), and hydrogen potential (pH). Additionally, an analysis of LoRa parameters was conducted for the rural area and the wetlands, where SF9 and SF10 show a packet reception rate higher than 97%. This is complemented by an energy assessment in relation to the LoRa interface, obtaining proper operation of the node. This scheme arises from the work developed in González et al. (Smart Cities: 5th Ibero-American Congress, ICSC-CITIES 2022, Cuenca, Ecuador, November 28–30, 2022, Revised Selected Papers. Springer, 2023), and due to the satisfactory results, the data collection is further explored, and its behavior is detailed. In this sense, a comparison of the prototype’s measurements with a commercial equipment was performed, the experiments indicate that the temperature and pH sensors provide comparable data with the commercial equipment. The primary achievement of this study is the development of an affordable, portable, and open-source prototype aimed at transmitting hydrological information from Andean high-altitude lakes using IoT technologies.
URI : http://dspace.ucuenca.edu.ec/handle/123456789/44114
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85181479901&doi=10.1007%2fs42979-023-02515-4&partnerID=40&md5=3dd911749be84c165d9b1e1a28a9c144
URI Fuente: https://link.springer.com/journal/42979
ISSN : 2661-8907
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
documento.pdf
  Until 2050-12-30
1.95 MBAdobe PDFVisualizar/Abrir     Solicitar una copia


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00