Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: https://dspace.ucuenca.edu.ec/handle/123456789/42590
Título : Comparative Fracture Resistance Analysis of Translucent Monolithic Zirconia Dioxide Milled in a CAD/CAM System
Autor: Paltán Zhingre, César Antonio
Abad Coronel, Cristian Gustavo
Paladines Diaz, Maria De los angeles
Ulloa Wilches, Ana Liz
Fajardo Seminario, Jorge Isaac
Correspondencia: Abad Coronel, Cristian Gustavo, cristian.abad@ucuenca.edu.ec
Palabras clave : CAD CAM materials
Zirconia
Monolithic
Multilayer zirconia
Fracture resistance
Área de conocimiento FRASCATI amplio: 3. Ciencias Médicas y de la Salud
Área de conocimiento FRASCATI detallado: 3.2.15 Odontología
Área de conocimiento FRASCATI específico: 3.2 Medicina Clínica
Área de conocimiento UNESCO amplio: 09 - Salud y Bienestar
ÁArea de conocimiento UNESCO detallado: 0911 - Estudios Dentales
Área de conocimiento UNESCO específico: 091 - Salud
Fecha de publicación : 2023
Volumen: Volumen 6, número 2
Fuente: Ceramics
metadata.dc.identifier.doi: Comparative Fracture Resistance Analysis of Translucent Monolithic Zirconia Dioxide Milled in a CAD/CAM System
Tipo: ARTÍCULO
Abstract: 
The aim of this study was to evaluate and compare the fracture resistance of definitive zirconia dioxide restorations obtained using a computer-aided design and manufacturing (CAD/CAM) system. Methods: Two groups of ten samples were analyzed for each material (n: 20); the first group was Zolid Gen X Amann Girrbach (ZGX) and the second group was Cercon HT Dentsply Sirona (CDS). The restorations were designed with identical parameters and milled with a CAD/CAM system. Each specimen was load tested at a speed of 0.5 mm/min, with a direction parallel to the major axis of the tooth and with an initial preload of 10 N until fracture using a universal testing machine (Universal/Tensile Testing Machine, Autograph AGS-X Series) equipped with a 20 kN load cell. The results obtained were recorded in Newtons (N), using software connected to the testing machine. Results: Statistically significant differences were found, and the fracture resistance of the monolithic zirconia crowns was lower in the CDS group (1744.84 172.8 N) compared to the ZGX group (2387.41 516 N). Conclusions: The monolithic zirconia CAD-CAM zirconia crowns showed sufficient fracture resistance when used in posterior molar and premolar zones with either material, as they withstood fracture loads greater than the maximum masticatory force.
URI : http://dspace.ucuenca.edu.ec/handle/123456789/42590
https://www.scopus.com/record/display.uri?eid=2-s2.0-85163973582&origin=resultslist&sort=plf-f&src=s&sid=579f4833a66a3f5e9fb4e07259d0e897&sot=b&sdt=b&s=TITLE-ABS-KEY%28Comparative+Fracture+Resistance+Analysis+of+Translucent+Monolithic+Zirconia+Dioxide+Milled+in+a+CAD%2FCAM+System%29&sl=125&sessionSearchId=579f4833a66a3f5e9fb4e07259d0e897
URI Fuente: https://www.mdpi.com/2571-6131/6
ISSN : 2571-6131
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
documento.pdf218.29 kBAdobe PDFVisualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00