Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: https://dspace.ucuenca.edu.ec/handle/123456789/42322
Título : Modified First Stage of French Vertical Flow Constructed Wetlands performance during extreme operation conditions
Autor: Arévalo Durazno, María Belén
Garcia Zumalacarregui, Jorge Alejandro
Ho, Long
Narváez, Andrea
Alvarado, Andrés
Correspondencia: Arévalo Durazno, María Belén, barevalo@uazuay.edu.ec
Palabras clave : First stage of French vertical flow constructed wetlands
Hydraulic loading rate
Municipal wastewater
Tropical Andes
Área de conocimiento FRASCATI amplio: 2. Ingeniería y Tecnología
Área de conocimiento FRASCATI detallado: 2.7.1 Ingeniería Ambiental y Geológica
Área de conocimiento FRASCATI específico: 2.7 Ingeniería del Medio Ambiente
Área de conocimiento UNESCO amplio: 07 - Ingeniería, Industria y Construcción
ÁArea de conocimiento UNESCO detallado: 0712 - Tecnología de Protección del Medio Ambiente
Área de conocimiento UNESCO específico: 071 - Ingeniería y Profesiones Afines
Fecha de publicación : 2022
Volumen: Volumen 0, número 0
Fuente: IWA 17th International Conference on Wetland Systems for Water Pollution Control
metadata.dc.identifier.doi: 10.2166/wst.2023.201
Editor: INRAE, INSA
Ciudad: 
Lyon
Tipo: ARTÍCULO DE CONFERENCIA
Abstract: 
This study applied two Modified First Stage of French Vertical Flow Constructed Wetlands pilots for the treatment of sewage coming from a combined sewer system under extreme hydraulic loads and medium temperatures at high altitude. Particularly, the pilot-scale experiment was conducted within nine months after their start-up period of four months. During this period, two different high hydraulic loading rates (0.94 m d-1 and 0.56 m d-1) representing 2.5 and 1.5 times the design values respectively, were applied to investigate the impact of HLRs on the performance of the treatment system. The observed performances for COD and TSS removals were satisfactory, with average values of 53% and 66% respectively. Moreover, reducing the HLR resulted in higher removal efficiency for COD (from 46% to 64%) but not for TSS (from 67% to 64%). From these findings, it is suggested that high HLRs can be applied for the First Stage of the French System without compromising the operation of the units and obtaining satisfactory results, especially in case of diluted wastewater and severe area restrictions.
URI : https://iwaponline.com/wst/article/doi/10.2166/wst.2023.201/95922/Performance-of-modified-first-stage-French
URI Fuente: https://www.icws2022.insight-outside.fr/en/program/program/13
ISBN : 978-2-9585706-0-6
ISSN : 0273-1223, e 1996-9732
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
documento.pdf388.2 kBAdobe PDFVisualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00