Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: https://dspace.ucuenca.edu.ec/handle/123456789/40425
Título : Analysis of the mesh resolution of an .STL exported from an intraoral scanner file
Autor: Atria, Pablo J
Abad Coronel, Cristian Gustavo
Blatz, Markus
Pendola, Martin
Mena Cordova, Nancy Cecilia
Cornejo, Julián
Romero Muñoz, Carla Estefania
Correspondencia: Atria, Pablo J, atria.pablo@gmail.com
Palabras clave : Dental materials
CAD CAM
Digital dentistry
Área de conocimiento FRASCATI amplio: 3. Ciencias Médicas y de la Salud
Área de conocimiento FRASCATI detallado: 3.2.15 Odontología
Área de conocimiento FRASCATI específico: 3.2 Medicina Clínica
Área de conocimiento UNESCO amplio: 09 - Salud y Bienestar
ÁArea de conocimiento UNESCO detallado: 0911 - Estudios Dentales
Área de conocimiento UNESCO específico: 091 - Salud
Fecha de publicación : 2022
Fecha de fin de embargo: 27-dic-2050
Volumen: volumen 4, número 5
Fuente: Journal of Esthetic and Restorative Dentistry
metadata.dc.identifier.doi: 10.1111/jerd.12889
Tipo: ARTÍCULO
Abstract: 
Objectives: This study aimed to provide information on the accuracy of exported digital files with the different resolutions available in the CEREC 4.6.2 software obtained by means of an intraoral scanner (IOS), in addition to establishing differences between materialized models with different exported resolutions, and how these different exported files can influence finite element analysis (FEA) simulations. Materials and Methods: The upper complete arch of 10 patients was scanned through an IOS (CEREC Omnicam 1.0/Dentsply Sirona). Files of three resolution meshes digitalized by a CAD software (Cerec SW, 4.6.2) high, medium and low (IOSH, IOSM, and IOSL) were exported. Each file was evaluated by a software (NETFABB) about the number of triangles obtained and compared with the number announced by the manufacturer. Also, with a superimposition with a specialized software (GEOMAGIC X), the digital models were compared. The files of each resolution were printed (Sprintray 3D Printer), and the printed models were scanned with IOS (Omnicam 1.0) and compared with the control group (intraoral scanned high-resolution file, IOSH). FEA simulations were imported into COMSOL and analyzed under different loading conditions. Results: The number of exported triangles coincided with that reported by the manufacturer. The digital models from files of different resolution did not show significant differences (less than 1.5 um) between each other. Models printed (H, M, L) from files of the same resolution mesh (H, M, L) did not show significant differences between them either in partial measures of the arch and neither in the complete arch. FEA showed significant differences in stress concentration between different exported models. Clinical Significance: Digital models can be exported and printed in three resolutions of the mesh, without differences clinically significative. On the other hand, for future FEA applications further research should be performed in order to determine the optimal number of triangles.
URI : http://dspace.ucuenca.edu.ec/handle/123456789/40425
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85125571393&doi=10.1111%2fjerd.12889&partnerID=40&md5=25fe91e996e13b626e50ba364764fd40
URI Fuente: https://onlinelibrary.wiley.com/journal/17088240
ISSN : 1708-8240
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
prePostPrint.pdfprePostPrint3.27 MBAdobe PDFVisualizar/Abrir
documento.pdf
  Until 2050-12-27
document3.27 MBAdobe PDFVisualizar/Abrir     Solicitar una copia


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00