Logo Repositorio Institucional

Please use this identifier to cite or link to this item: https://dspace.ucuenca.edu.ec/handle/123456789/38810
Title: Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador
Authors: Ajila Bohórquez, Ana Mischell
Lalangui Matamoros, Joe Javier
metadata.dc.contributor.advisor: Palacios Astudillo, Iván Andrés
metadata.dc.ucuenca.correspondencia: anita.ajilabohórquez@gmail.com
joejavierlm@gmail.com
metadata.dc.subject.other: Fotometría
Keywords: Odontología
Fotopolimerización
Fibra óptica
Radiómetro dental
metadata.dc.ucuenca.areaconocimientounescoamplio: 32 Ciencias Médicas
metadata.dc.ucuenca.areaconocimientounescodetallado: 3311.03 Instrumentos para Odontología
metadata.dc.ucuenca.areaconocimientounescoespecifico: 3213 Cirugía
Issue Date: 20-Jan-2021
metadata.dc.format.extent: 17 páginas
Publisher: Universidad de Cuenca
metadata.dc.description.city: 
Cuenca
Series/Report no.: ODON;656
metadata.dc.type: Article
Abstract: 
Introduction: Light intensity emitted by the curing lamps represents an essential factor in the activation of photosensitive materials. The adequate supply of intensity, as well as the correct functioning of the device, it ensures a correct dental treatment. Objective: To know the light intensity, type, and fiber state of the curing lamps used in private dental offices in the city of Cuenca - Ecuador. Materials and methods: The cross-sectional descriptive study assessed the light intensity of 366 light-curing lamps from private clinics with the use of a Bluephase Meter II radiometer, besides the Likert-scale based evaluation of its type and condition. Data analysis was done with the software R v.3.2 and its interface R-Studio v.1.2. Results: Inadequate light intensities were observed in 18% of the total analyzed units. Inadequate light intensities corresponded at 46% of Halogen lamps, and 12% of LED units. Likewise, 17% of units presented fiber fracture, while 52% showed residues of biomaterials on it. The predominant diameter in the units was 8mm, representing 65% of the total of light-curing lamps analyzed. Conclusions: LED lamps presented adequate light intensities in higher proportion in comparison to halogen lamps. It was shown that the presence of fractures and residues decrease the intensity of the photocuring units. Furthermore, we indicate that a periodic control of the lightcuring units is necessary to prevent future problems in oral treatments.
metadata.dc.description.degree: 
Odontólogo
URI: http://dspace.ucuenca.edu.ec/handle/123456789/38810
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
Trabajo de titulación.pdfVersión presentada (texto completo)318.58 kBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



This item is licensed under a Creative Commons License Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00