Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: https://dspace.ucuenca.edu.ec/handle/123456789/38488
Título : A new approach for scaling up fixed-bed adsorption columns for aqueous systems: a case of antibiotic removal on natural adsorbent
Autor: Juela Quintuna, Diego Marcelo
Vera Cabezas, Luisa Mayra
Cruzat Contreras, Christian Americo
Astudillo Aleman, Ana Lucia
Vanegas Pena, Maria Eulalia
Correspondencia: Vanegas Pena, Maria Eulalia, eulalia.vanegas@ucuenca.edu.ec
Palabras clave : Scaling up
Wastewater treatment
Antibiotic removal
Biosorption
Modeling
Área de conocimiento FRASCATI amplio: 2. Ingeniería y Tecnología
Área de conocimiento FRASCATI detallado: 2.4.2 Ingeniería de Procesos Químicos
Área de conocimiento FRASCATI específico: 2.4 Ingeniería Química
Área de conocimiento UNESCO amplio: 05 - Ciencias Físicas, Ciencias Naturales, Matemáticas y Estadísticas
ÁArea de conocimiento UNESCO detallado: 0521 - Ciencias Ambientales
Área de conocimiento UNESCO específico: 052 - Medio Ambiente
Fecha de publicación : 2022
Volumen: Volumen 159
Fuente: Process Safety and Environmental Protection
metadata.dc.identifier.doi: 10.1016/j.psep.2022.01.046
Tipo: ARTÍCULO
Abstract: 
The scaling up of adsorption columns is a crucial step toward the removal of emerging pollutants from domestic and industrial wastewaters. In this study, a fixed-bed column to remove sulfamethoxazole packed with sugarcane bagasse was scaled up from laboratory (DL = 2.2 cm) to pilot unit (DP = 4.4 cm) using a scaling factor (K = 2). In addition to the basic similarity rules for scaling, three new criteria were proposed for the mass adsorbent, flow rate, and bed volume. Then, three lab-scale tests at flow rate of 5 mL/min and bed heights of 15, 25, and 35 cm were transferred to the pilot-scale column at flow rate of 20 mL/min and bed heights of 30, 50, and 70 cm, respectively. The breakthrough curves and the fixed-bed parameters (residence time tR, saturation time ts, adsorption capacity qe, volume of solution treated Vef, and removal percentage %R) obtained in both scales were compared to define their effect with the increase of scale. Finally, a mechanistic model was proposed to predict the breakthrough curves in both columns. The results exhibited that the breakthrough curves in the pilot-scale prolonged in time with higher breakthrough and saturation times than the laboratory breakthrough data. Additionally, tR, ts, and Vef changed in function of the K value used: ts and tR doubled their value in the pilot column or ; Vef was eight times higher in the pilot column than the lab-column or ; qe and %R remained constant in both scales; these results were corroborated with the predicted breakthrough curves. Besides, the mechanistic model predicted with great precision the breakthrough data in both scales (R2>0.9), which means that the model can be used confidently for scaling up purposes. This study demonstrated new criteria which can be easily applied to scale up adsorption columns whit results that showed a correlation between both scales.
URI : https://www.scopus.com/record/display.uri?eid=2-s2.0-85123846485&origin=resultslist&sort=plf-f&src=s&sot=b&sdt=b&s=TITLE-ABS-KEY%28A+new+approach+for+scaling+up+fixed-bed+adsorption+columns+for+aqueous+systems%3A+a+case+of+antibiotic+removal+on+natural+adsorbent%29
URI Fuente: https://www.sciencedirect.com/journal/process-safety-and-environmental-protection
ISSN : 09575820, e 1744-3598
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
documento.pdf395.61 kBAdobe PDFVisualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00