Título : The energy saving potential of retrofitting a smart heating system: a residence hall pilot study
Autor: Nowé, Ann
De Bock, Yannick
Auquilla Sangolqui, Andres Vinicio
Bracquené, Ellen
Duflou, Joost R.
Correspondencia: De Bock, Yannick, yannick.debock@kuleuven.be
Palabras clave : Occupancy prediction
Building automation
Smart home
Energy management
Energy conservation
Smart thermostat
Área de conocimiento FRASCATI amplio: 2. Ingeniería y Tecnología
Área de conocimiento FRASCATI detallado: 2.2.2 Robótica y Control Automático
Área de conocimiento FRASCATI específico: 2.2 Ingenierias Eléctrica, Electrónica e Información
Área de conocimiento UNESCO amplio: 07 - Ingeniería, Industria y Construcción
ÁArea de conocimiento UNESCO detallado: 0713 - Electricidad y Energia
Área de conocimiento UNESCO específico: 071 - Ingeniería y Profesiones Afines
Fecha de publicación : 2021
Volumen: Volumen 31
Fuente: Sustainable computing: informatics and systems
metadata.dc.identifier.doi: 10.1016/j.suscom.2021.100585
Tipo: ARTÍCULO
Abstract: 
Energy conservation is of increasing importance in contemporary society. A large fraction of energy end-use can be attributed to space conditioning. Therefore, intelligent control systems were devised and commercialised in the form of smart thermostats. Hereto, the availability of occupancy information is essential such that heating and/or cooling schedules can be tailored to user needs. This way energy savings can be obtained without jeopardising user satisfaction. However, preceding studies generally rely on simulations to estimate the potential reduction in energy consumption. This work aims at quantifying the potential based on a real life experiment. The development of a smart heating system is presented along with the results of an actual field test of retrofitting this system in 14 single-user student rooms of a university residence hall. An experiment was conducted in which the heating was automatically steered for 1 week (26 March 2018–01 April 2018). Total energy savings range between 26.9% and 59.5% and calculated thermal comfort was not significantly affected by the autonomous control. Furthermore, an environmental impact reduction of 3.2 to 12.9 EcoPoints is estimated for the controlled week, resulting in a reduction of 37.5 to 150.2
URI : http://dspace.ucuenca.edu.ec/handle/123456789/38151
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85109105989&doi=10.1016%2fj.suscom.2021.100585&partnerID=40&md5=29817e72168cb49e5e95eb8245ba2b32
URI Fuente: https://www.sciencedirect.com/journal/sustainable-computing-informatics-and-systems
ISSN : 2210-5379
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
documento.pdfdocument2.59 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00