Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: https://dspace.ucuenca.edu.ec/handle/123456789/5352
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorOchoa Figueroa, Edgar Efraín-
dc.contributor.authorMartínez Alvarez, Guido Francisco-
dc.contributor.authorMedina Velecela, Andrés Esteban-
dc.date.accessioned2014-04-07T14:47:14Z-
dc.date.available2014-04-07T14:47:14Z-
dc.date.issued2014-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/5352-
dc.descriptionEl objetivo del presente proyecto es el de brindar una solución para la empresa municipal de Cuenca ETAPA EP, esta empresa consta con un sistema de monitoreo de sus nodos, basado en el protocolo SNMP, con este sistema se puede alertar de fallas en los diversos equipos con los que cuenta la empresa. Sin embargo existen ciertos equipos, los cuales todavía no constan dentro de esta matriz de control y monitoreo, es así que surge el planteamiento de esta tesis, La propuesta es la de implementar un sistema confiable, eficiente y rentable, de modo que pueda ser replicado en otras centrales que no cuentan con un monitoreo integral de parámetros, así como el brindar a los operarios de red la capacidad para gestionar los valores de las variables de manera remota. Se realiza un análisis y un diseño basado en el uso de un micro controlador de la familia MICROCHIP, el cual es el PIC18F4620y un módulo para comunicación en red denominado ENC28J60, en el primero es donde se implementan las capas superiores de red del protocolo TCPIP y la lectura de datos provenientes desde distintos sensores, explicados a detalle en este documento, en el módulo de comunicación es en donde se implementa la capa física y la de enlace de datos.es_ES
dc.description.abstractThis thesis work focuses on the development of a system by which network administrators from ETAPA EP, a telecom provider from the city of Cuenca, Ecuador, will be able to remotely either prevent or troubleshoot node failures based on the occurrence of energy outages, therefore in this project there have been first developed current and voltage sensors for the three phase distribution line, as well as sensors in order to monitor the back-up energy system, which consists of a generator and two battery banks. A node security and temperature monitoring scheme has been also taken into account. An analysis on the communication system able to meet the enterprises network parameters in order to send information from the sensors or to receive commands to trigger relays is provided in detail, this study includes both the hardware and software specifications and guidelines required to set up this system. In order for someone to replicate a remote sensor monitoring system such as this one, the reader is expected to have a solid understanding of electronics, networking, SNMP, as well as C programming skills.es_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.relation.ispartofseriesTET;5-
dc.rightsopenAccess-
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectElectrónicaes_ES
dc.subjectMicrocontroladoreses_ES
dc.subjectProtocolos de redes_ES
dc.subjectCantón Cuencaes_ES
dc.titleDiseño e implementación de un módulo SNMP para el control y monitoreo de nodos de la Empresa ETAPA EPes_ES
dc.typebachelorThesises_ES
dc.ucuenca.paginacion101 páginases_ES
dc.description.degreeIngeniero en Electrónica y Telecomunicacioneses_ES
dc.description.cityCuenca, Ecuadores_ES
dc.ucuenca.id0102134574es_ES
Aparece en las colecciones: Tesis de Pregrado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Trabajo-de-Titulación.pdfVersión presentada (texto completo)3.5 MBAdobe PDFVisualizar/Abrir


Este ítem está protegido por copyright original



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00