Title: An experimental comparison of model-based fault detection and isolation techniques in a multi-tank system
Authors: Minchala Avila, Luis Ismael
Guzman Guillen, Galo Fernando
Duran Siguenza, Juan Francisco
metadata.dc.ucuenca.correspondencia: Minchala Avila, Luis Ismael, ismael.minchala@ucuenca.edu.ec
Keywords: Fault detection and Isolation
Tank-interconnected system
Parameter estimation
Kalman filter
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.2.4 Ingeniería de La Comunicación y de Sistemas
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.2 Ingenierias Eléctrica, Electrónica e Información
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0714 - Electrónica y Automatización
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2024
metadata.dc.ucuenca.embargoend: 31-Dec-2060
metadata.dc.ucuenca.volumen: Volumen 0, número 0
metadata.dc.source: 8th IEEE Ecuador Technical Chapters Meeting
metadata.dc.identifier.doi: 10.1109/ETCM63562.2024.10746149
Publisher: IEEE
metadata.dc.description.city: 
Cuenca
metadata.dc.type: ARTÍCULO DE CONFERENCIA
Abstract: 
Fault detection and isolation (FDI) systems ensure processes' safety, reliability, and secure operation. Many techniques proposed in the literature work well in simulation scenarios, but perform poorly in realistic systems with significant noise. This work presents a hybrid-based technique that uses an extended Kalman filter to smooth out measurements and parameter estimation of a nonlinear second-order model for quantifying leakage faults in an interconnected multi-tank system. The cost function for parameter estimation minimizes the squared error between predictions and measurements. The experimental results demonstrate that the proposed hybrid technique yielded a better estimate than the baseline FDI techniques. The proposed technique improved the prediction of tank dynamics and fault estimation quality by about 32%.
URI: https://dspace.ucuenca.edu.ec/handle/123456789/45751
https://www.scopus.com/record/display.uri?eid=2-s2.0-85211765927&origin=resultslist&sort=plf-f&src=s&sot=b&sdt=b&s=TITLE-ABS-KEY%28An+experimental+comparison+of+model-based+fault+detection+and+isolation+techniques+in+a+multi-tank+system%29&sessionSearchId=03e097934ad81ac05f2d7b340cdeed74&relpos=0
metadata.dc.ucuenca.urifuente: https://attend.ieee.org/etcm-2024/
ISBN: 979-835039158-9
ISSN: 1057-7149
Appears in Collections:Artículos

Files in This Item:
File SizeFormat 
documento.pdf
  Until 2060-12-31
386.68 kBAdobe PDFView/Open Request a copy


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00