Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: https://dspace.ucuenca.edu.ec/handle/123456789/45592
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorMoscoso Romo, María Paz-
dc.contributor.authorLlanos Chacón, Karla Nicole-
dc.contributor.authorRamón Godoy, Daniela Lisbeth-
dc.date.accessioned2024-10-16T12:33:30Z-
dc.date.available2024-10-16T12:33:30Z-
dc.date.issued2024-10-15-
dc.identifier.urihttps://dspace.ucuenca.edu.ec/handle/123456789/45592-
dc.descriptionIntroducción: Las infecciones asociadas a la asistencia sanitaria (IAAS) son una amenaza para la salud a nivel mundial dado que representan una de las principales causas de morbimortalidad. Estas infecciones pueden surgir por la presencia de microorganismos patógenos en superficies u objetos inertes. Objetivo: Analizar el estado microbiológico de las superficies inertes en el área de Consulta Externa y Emergencia del centro de salud “Mariano Estrella”, en la ciudad de Cuenca, Azuay. Metodología: Se tomaron 250 muestras por el método de hisopado, según la norma ISO 14698-1; las cuales fueron transportadas y procesadas en el Laboratorio de Microbiología de la Facultad de Ciencias Químicas de la Universidad de Cuenca. Resultados: Se evidenció crecimiento en el 90% de las muestras, obteniendo una carga microbiana de 2.52 UFC/cm2 y 419 UFC/superficie en superficies regulares e irregulares, respectivamente. Se identificaron 372 cepas bacterianas, siendo Staphylococcus coagulasa negativa (37%) el más frecuente, seguido de Bacillus spp (24%), Enterobacter cloacae (13%), y Staphylococcus aureus (6%). De los microorganismos considerados como patógenos, se realizaron pruebas de detección fenotípica de mecanismos de resistencia a los antibióticos, descartando para todas las cepas analizadas, resistencias adquirida. De las superficies inertes analizadas, se determinó que las más susceptibles a contaminación microbiana fueron teclados y mouse de computadores. Conclusión: Los resultados de este estudio permitieron inferir que los procesos de limpieza y desinfección llevados a cabo en el centro de salud “Mariano Estrella” no son los adecuados, existiendo un riesgo elevado de aparición de IAAS.en_US
dc.description.abstractIntroduction: Healthcare-associated infections (HAIs) are a global health threat since they represent one of the leading causes of morbidity and mortality. These infections can arise from the presence of pathogenic microorganisms on surfaces or inert objects. Objective: To analyze the microbiological status of inert surfaces in the Outpatient and Emergency area of the “Mariano Estrella” health center in the city of Cuenca, Azuay. Methodology: 250 samples were taken by the swabbing method, according to ISO 14698-1; they were transported and processed in the Microbiology Laboratory of the Faculty of Chemical Sciences of the University of Cuenca. Results: Growth was evidenced in 90% of the samples, obtaining a microbial load of 2.52 CFU/cm2 and 419 CFU/surface in regular and irregular surfaces, respectively. A total of 372 bacterial strains were identified, with coagulase-negative Staphylococcus (37%) being the most frequent, followed by Bacillus spp (24%), Enterobacter cloacae (13%), and Staphylococcus aureus (6%). Of the inert surfaces analyzed, it was determined that the most susceptible to microbial contamination were computer keyboards and mice. On the other hand, the microorganisms considered as pathogens were tested for susceptibility to antibiotics, ruling out acquired resistance for all the strains analyzed. Conclusion: The results of this study allowed inferring that the cleaning and disinfection processes carried out in the “Mariano Estrella” health center are not adequate, and that there is a high risk of HAIs.en_US
dc.description.uri0000-0002-5736-6201en_US
dc.formatapplication/pdfen_US
dc.format.extent112 páginasen_US
dc.language.isospaen_US
dc.publisherUniversidad de Cuencaen_US
dc.relation.ispartofTBQ;915-
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectBioquímicaen_US
dc.subjectMicrobiologíaen_US
dc.subjectInfeccionesen_US
dc.subjectAsistencia sanitariaen_US
dc.subject.otherClasificación de la Investigación::Bioquímicaen_US
dc.titleAnálisis microbiológico en el área de consulta externa y emergencia en el Centro de Salud “Mariano Estrella” de la ciudad de Cuenca-Provincia del Azuayen_US
dc.title.alternativeAnálisis Microbiológico en el Área de Consulta Externa y Emergencia en el Centro de Salud “Mariano Estrella” de la Ciudad de Cuenca-Provincia del Azuayen_US
dcterms.descriptionBioquímico Farmacéuticoen_US
dcterms.spatialCuenca, Ecuadoren_US
dc.rights.accessRightsopenAccessen_US
Aparece en las colecciones: Tesis de Pregrado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Trabajo-de-Titulación.pdfVersión presentada (texto completo)7.08 MBAdobe PDFVisualizar/Abrir


Este ítem está protegido por copyright original



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00