Por favor, use este identificador para citar o enlazar este ítem:
https://dspace.ucuenca.edu.ec/handle/123456789/43496Registro completo de metadatos
| Campo DC | Valor | Lengua/Idioma |
|---|---|---|
| dc.contributor.advisor | Larriva Loyola, Jaime Alejandro | - |
| dc.contributor.author | Paladines Díaz, María de los Ángeles | - |
| dc.contributor.author | Ulloa Wilches, Ana Liz | - |
| dc.date.accessioned | 2023-12-12T14:49:41Z | - |
| dc.date.available | 2023-12-12T14:49:41Z | - |
| dc.date.issued | 2023-12-12 | - |
| dc.identifier.uri | http://dspace.ucuenca.edu.ec/handle/123456789/43496 | - |
| dc.description | El objetivo de este estudio fue evaluar y comparar la resistencia a la fractura de restauraciones definitivas de dióxido de Zirconio obtenidas mediante un sistema de diseño y fabricación asistido por computadora (CAD/CAM). Métodos: Se analizaron dos grupos de diez muestras por cada material (n: 20), el primer grupo fue Zolid Gen X Amann Girrbach (ZGX) y el segundo grupo de Cercon HT Dentsply Sirona (CDS). Las restauraciones fueron diseñadas con parámetros idénticos y fresadas con un sistema CAD/CAM (CEREC SW 5.1, CEREC MCXL, Dentsply-SironaTM, Bensheim). Cada muestra fue sometida a una prueba de carga a una velocidad de 0,5 mm/min con una dirección paralela al eje mayor del diente y con una precarga inicial de 10N hasta la fractura utilizando una máquina de prueba universal (Universal/Tensile Testing Machine, Autograph AGS-X Series) equipada con una celda de carga de 20 kN. Los resultados obtenidos se registraron en Newtons (N), mediante un software conectado a la máquina de prueba (Software TRAPEZIUM LITE X). Resultados: Se encontraron diferencias estadísticamente significativas y la resistencia a la fractura de las coronas monolíticas de zirconio fue menor en el grupo CDS (1744,84 ± 172.8 N), en comparación con el grupo ZGX (2387.41 ± 516 N). Conclusiones: Las coronas monolíticas de zirconio CAD-CAM mostraron suficiente resistencia a la fractura para ser utilizadas en regiones de molares con cualquiera de los dos materiales ya que soportaron cargas de fractura mayores a la fuerza masticatoria máxima. | en_US |
| dc.description.abstract | The aim of this study was to evaluate and compare the fracture resistance of definitive zirconia dioxide restorations obtained using a computer-aided design and manufacturing (CAD/CAM) system. Methods: Two groups of ten samples were analyzed for each material (n: 20); the first group was Zolid Gen X Amann Girrbach (ZGX) and the second group was Cercon HT Dentsply Sirona (CDS). The restorations were designed with identical parameters and milled with a CAD/CAM system. Each specimen was load tested at a speed of 0.5 mm/min, with a direction parallel to the major axis of the tooth and with an initial preload of 10 N until fracture using a universal testing machine (Universal/Tensile Testing Machine, Autograph AGS-X Series) equipped with a 20 kN load cell. The results obtained were recorded in Newtons (N), using software connected to the testing machine. Results: Statistically significant differences were found, and the fracture resistance of the monolithic zirconia crowns was lower in the CDS group (1744.84 ± 172.8 N) compared to the ZGX group (2387.41 ± 516 N). Conclusions: The monolithic zirconia CAD-CAM zirconia crowns showed sufficient fracture resistance when used in posterior molar and premolar zones with either material, as they withstood fracture loads greater than the maximum masticatory force. | en_US |
| dc.description.uri | 0000-0003-0555-3571 | en_US |
| dc.format | application/pdf | en_US |
| dc.format.extent | 23 páginas | en_US |
| dc.language.iso | spa | en_US |
| dc.publisher | Universidad de Cuenca | en_US |
| dc.relation.ispartof | ODONOD;005 | - |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
| dc.subject | Restauración dental | en_US |
| dc.subject | Zirconio monolítico | en_US |
| dc.subject | Zirconio multilayer | en_US |
| dc.subject | Materiales dentales | en_US |
| dc.subject.other | CIUC::Medicina::Odontología::Restauración Dental | en_US |
| dc.title | Comparative fracture resistance analysis of translucent monolithic zirconia dioxide milled in a CAD/CAM system | en_US |
| dc.title.alternative | COMPARATIVE FRACTURE RESISTANCE ANALYSIS OF TRANSLUCENT MONOLITHIC ZIRCONIA DIOXIDE MILLED IN A CAD/CAM SYSTEM | en_US |
| dc.type | masterThesis | en_US |
| dcterms.description | Especialista en Operatoria dental y Estética | en_US |
| dcterms.spatial | Cuenca, Ecuador | en_US |
| dc.rights.accessRights | openAccess | en_US |
| Aparece en las colecciones: | Tesis Especializaciones | |
Ficheros en este ítem:
| Fichero | Descripción | Tamaño | Formato | |
|---|---|---|---|---|
| Trabajo-de-Titulación.pdf | Versión presentada (texto completo) | 2.21 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está protegido por copyright original |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons
Centro de Documentacion Regional "Juan Bautista Vázquez" | ||||||||||
| ||||||||||
