Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: https://dspace.ucuenca.edu.ec/handle/123456789/43038
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorAbad Coronel, Cristian Gustavo
dc.contributor.authorPazan Morales, Domenica Patricia
dc.contributor.authorLarriva Loyola, Jaime Alejandro
dc.contributor.authorHidalgo Tamayo, Maria Lorena
dc.date.accessioned2023-10-04T20:00:03Z-
dc.date.available2023-10-04T20:00:03Z-
dc.date.issued2023
dc.identifier.issn2304-6767
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/43038-
dc.identifier.urihttps://www.mdpi.com/2304-6767/11/9/216
dc.description.abstractWith the great demand in the market for new dental software, the need has been seen to carry out a precision study for applications in digital dentistry, for which there is no comparative study, and there is a general ignorance regarding their applications. The purpose of this study was to investigate the accuracy differences between digital impressions obtained using generic G-CAD (general CAD) and D-CAD (CAD dental) software. Today, there is a difference between the design software used in dentistry and these in common use. Thus, it is necessary to make a comparison of precision software for specific and generic dental use. We hypothesized that there is no significant difference between the software for specific and general dental use. Methods: A typodont was digitized with an intraoral scanner and the models obtained were exported in STL format to four different softwares (Autodesk MeshMixer 3.5, Exocad Dental, Blender for dental, and InLAB). The STL files obtained by each software were materialized using a 3D printer. The printed models were scanned and exported in STL files, with which six pairs of groups were formed. The groups were compared using analysis software (3D Geomagic Control X) by superimposing them in the initial alignment order and using the best fit method. Results: There were no significant differences between the four analyzed software types; however, group 4, composed of the combination of D-CAD (Blender– InLAB), obtained the highest average (􀀀0.0324 SD = 0.0456), with a higher accuracy compared to the group with the lowest average (group 5, composed of the combination of the Meshmixer and Blender models), a generic software and a specific software (0.1024 SD = 0.0819). Conclusion: Although no evidence of significant difference was found regarding the accuracy of 3D models produced by G-CAD and D-CAD, combinations of groups where specific dental design software was present showed higher accuracy (precision and trueness). The comparison of the 3D graphics obtained with the superimposition of the digital meshes of the printed models performed with the help of the analysis software using the best fit method, replicating the same five reference points for the six groups formed, evidenced a greater tolerance in the groups using D-CAD.
dc.language.isoes_ES
dc.sourceDentistry Journal
dc.subjectDigital workflow
dc.subject3D models
dc.subjectSoftware
dc.subjectCADCAM
dc.subjectSTL
dc.titleComparative Analysis between 3D-Printed Models Designed with Generic and Dental-Specific Software
dc.typeARTÍCULO
dc.ucuenca.idautor0301269916
dc.ucuenca.idautor0702927088
dc.ucuenca.idautor0107284440
dc.ucuenca.idautor0102211273
dc.identifier.doi10.3390/dj11090216
dc.ucuenca.versionVersión publicada
dc.ucuenca.areaconocimientounescoamplio09 - Salud y Bienestar
dc.ucuenca.afiliacionHidalgo, M., Universidad de Cuenca, Facultad de Odontología, Cuenca, Ecuador
dc.ucuenca.afiliacionPazan, D., Universidad de Cuenca, Facultad de Odontología, Cuenca, Ecuador
dc.ucuenca.afiliacionLarriva, J., Universidad de Cuenca, Facultad de Odontología, Cuenca, Ecuador
dc.ucuenca.afiliacionAbad, C., Universidad de Cuenca, Facultad de Odontología, Cuenca, Ecuador
dc.ucuenca.correspondenciaAbad Coronel, Cristian Gustavo, cristian.abad@ucuenca.edu.ec
dc.ucuenca.volumenVolumen 11, número 9
dc.ucuenca.indicebibliograficoSCOPUS
dc.ucuenca.factorimpacto0.536
dc.ucuenca.cuartilQ2
dc.ucuenca.numerocitaciones0
dc.ucuenca.areaconocimientofrascatiamplio3. Ciencias Médicas y de la Salud
dc.ucuenca.areaconocimientofrascatiespecifico3.2 Medicina Clínica
dc.ucuenca.areaconocimientofrascatidetallado3.2.15 Odontología
dc.ucuenca.areaconocimientounescoespecifico091 - Salud
dc.ucuenca.areaconocimientounescodetallado0911 - Estudios Dentales
dc.ucuenca.urifuentehttps://www.mdpi.com/journal/dentistry
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
documento.pdf2.1 MBAdobe PDFVisualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00