Logo Repositorio Institucional

Please use this identifier to cite or link to this item: https://dspace.ucuenca.edu.ec/handle/123456789/42953
Title: Smart monitoring method for photovoltaic systems and failure control based on power smoothing techniques
Authors: Arevalo Cordero, Wilian Paul
Benavides Padilla, Dario Javier
Keywords: Supercapacitor
Battery energy storage
Photovoltaic
Power smoothing
Renewable energy
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.2.4 Ingeniería de La Comunicación y de Sistemas
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.2 Ingenierias Eléctrica, Electrónica e Información
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0714 - Electrónica y Automatización
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2023
metadata.dc.ucuenca.embargoend: 31-Dec-2049
metadata.dc.ucuenca.volumen: Volume 205
metadata.dc.source: Renewable Energy
metadata.dc.identifier.doi: 10.1016/j.renene.2023.01.059
metadata.dc.type: ARTÍCULO
Abstract: 
In recent years, photovoltaic energy production has experienced significant progress, being integrated into the grid through large-scale distributed systems. The intermittent nature of solar irradiance coupled with the presence of photovoltaic failures causes fluctuations that could compromise the quality and stability of electrical grid. This paper presents a novel photovoltaic power smoothing method in a combination with moving averages and ramp rate to reduce fluctuations with hybrid storage systems (supercapacitors/batteries), the main novelty involves optimizing the number of charging/discharging cycles under PV failures. To achieve this goal, a photovoltaic failure detection method is proposed that uses machine learning to process big data by monitoring the behavior of photovoltaic. The experiments have been done under controlled conditions in the microgrid laboratory of the University of Cuenca. The results show the reduction of the supercapacitor operation with respect to other power smoothing methods. Moreover, the monitoring system is capable of detecting a failure in photovoltaic systems with a root mean squared error of 0.66 and the computational effort is reduced using the new smoothing technique. In this sense, the initial execution time is 4 times lower compared to the moving average method.
URI: http://dspace.ucuenca.edu.ec/handle/123456789/42953
https://www.scopus.com/record/display.uri?eid=2-s2.0-85147098182&origin=resultslist&sort=plf-f&src=s&sid=32959a0f8eb9c97e4d73f16e644c2236&sot=b&sdt=b&s=TITLE-ABS-KEY%28Smart+monitoring+method+for+photovoltaic+systems+and+failure+control+based+on+power+smoothing+techniques%29&sl=119&sessionSearchId=32959a0f8eb9c97e4d73f16e644c2236
metadata.dc.ucuenca.urifuente: https://www.sciencedirect.com/journal/renewable-energy
ISSN: 0960-1481
Appears in Collections:Artículos

Files in This Item:
File SizeFormat 
documento.pdf
  Until 2049-12-31
19.19 MBAdobe PDFView/Open Request a copy


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00