Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: https://dspace.ucuenca.edu.ec/handle/123456789/41630
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorTorres Portelles, Oclides-
dc.contributor.authorAmaya Ortega, Adriana Sofía-
dc.date.accessioned2023-04-05T20:22:37Z-
dc.date.available2023-04-05T20:22:37Z-
dc.date.issued2023-03-05-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/41630-
dc.descriptionAntecedentes: la tomografía axial computarizada es un estudio diagnóstico de imagen ampliamente utilizado durante los últimos años por su alta especificidad, sin embargo, la exposición a la radiación ionizante ha generado controversias en el personal médico por los posibles daños o mutaciones que este pudiese causar en el tejido. Objetivo: determinar la dosis de radiación en tomografía computarizada en pacientes atendidos en el Hospital Vicente Corral Moscoso durante el año 2019. Materiales y métodos: se trata de un estudio retrospectivo de cohorte transversal. Se incluyeron 296 expedientes clínicos de pacientes que cumplieron los criterios de inclusión. La información fue analizada mediante el programa estadístico SPSS versión 15.0, aplicándose estadística descriptiva. Resultados: 72% de pacientes se realizaron tomografías simples y 49.3% contrastadas. Las regiones anatómicas más estudiadas fueron las estructuras de cabeza y cuello con 65.9%. El 90.9% de los casos que se realizaron TC simple y contrastada, la dosis efectiva de radiación fue baja (0-50 mSV); en las personas en las que se efectúo solo TC simple, en el 4.4% se categorizó como riesgo medio y un 2.4% alto; y en los participantes que se sometieron a TC contrastada, el 2.7% y 2% se consideraron como riesgo medio y alto respectivamente. Según la radiación acumulada, 81.4% presentaron riesgo bajo; en la TC simple el 8.4% riesgo medio en contraste con 7.4% de la TC contrastada y 4.7% versus 3.7% de riesgo alto en la TC simple y contrastada respectivamente.en_US
dc.description.abstractBackground: computerized axial tomography is a diagnostic imaging study widely used in recent years due to its high specificity, however, exposure to ionizing radiation has generated controversy among medical personnel due to possible damage or mutations that it could cause in the tissue. Objective: to determine the radiation dose in computed tomography in patients treated at the Vicente Corral Moscoso Hospital during the year 2019. Materials and methods: this is a retrospective cross-sectional cohort study. 296 clinical records of patients who met the inclusion criteria were included. The information was analyzed using the statistical program SPSS version 15.0, applying descriptive statistics. Results: 72% of patients underwent simple tomographies and 49.3% contrasted. The most studied anatomical regions were the head and neck structures with 65.9%. In 90.9% of the cases that underwent simple and contrast CT, the effective dose of radiation was low (0-50 mSV); in the people in whom only a simple CT was performed, 4.4% were categorized as medium risk and 2.4% high; and in participants who underwent contrast-enhanced CT, 2.7% and 2% were considered medium and high risk respectively. According to the accumulated radiation, 81.4% presented low risk; in simple CT 8.4% medium risk in contrast to 7.4% in contrast-enhanced CT and 4.7% versus 3.7% high risk in simple and contrast-enhanced CT respectively.en_US
dc.description.uri0009-0001-8441-6980en_US
dc.formatapplication/pdfen_US
dc.format.extent17 páginasen_US
dc.language.isospaen_US
dc.publisherUniversidad de Cuencaen_US
dc.relation.ispartofseriesMEDI;075-
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectMedicinaen_US
dc.subjectRadiaciónen_US
dc.subjectTomografíaen_US
dc.subjectMedicina nuclearen_US
dc.subject.otherRadiologíaen_US
dc.titleDosis acumulada de radiación en tomografía computarizada en pacientes atendidos en el Hospital Vicente Corral Moscoso, Cuenca, año 2019en_US
dc.typemasterThesisen_US
dc.description.degreeEspecialista en Imagenologíaen_US
dc.description.cityCuencaen_US
dc.ucuenca.versionsubmittedVersionen_US
dc.ucuenca.areaconocimientounescoespecifico3201 Ciencias Clínicasen_US
dc.ucuenca.areaconocimientounescodetallado3201.11 Radiologíaen_US
dc.rights.accessRightsopenAccessen_US
dc.ucuenca.responsablerecepcionCarrión Román Daniel Ramiroen_US
Aparece en las colecciones: Tesis Especializaciones

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Trabajo-de-Titulacion.pdfVersión presentada (texto completo)389 kBAdobe PDFVisualizar/Abrir


Este ítem está protegido por copyright original



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00