Título : Improving reference evapotranspiration (ETo) calculation under limited data conditions in the high Tropical Andes
Autor: Cordova Mora, Mario Andres
Carrillo Rojas, Galo Jose
Vasquez Ojeda, Cristina Alejandra
Celleri Alvear, Rolando Enrique
Correspondencia: Vasquez Ojeda, Cristina Alejandra, cristina.vasquezo@ucuenca.edu.ec
Palabras clave : Páramo
Calibration
PM-ETo
Vapor pressure deficit
Solar radiation
Área de conocimiento FRASCATI amplio: 2. Ingeniería y Tecnología
Área de conocimiento FRASCATI detallado: 2.7.1 Ingeniería Ambiental y Geológica
Área de conocimiento FRASCATI específico: 2.7 Ingeniería del Medio Ambiente
Área de conocimiento UNESCO amplio: 05 - Ciencias Físicas, Ciencias Naturales, Matemáticas y Estadísticas
ÁArea de conocimiento UNESCO detallado: 0521 - Ciencias Ambientales
Área de conocimiento UNESCO específico: 052 - Medio Ambiente
Fecha de publicación : 2022
Volumen: Volumen 262
Fuente: Agricultural Water Management
metadata.dc.identifier.doi: 10.1016/j.agwat.2021.107439
Tipo: ARTÍCULO
Abstract: 
The computation of the reference crop evapotranspiration (ETo) using the FAO56 Penman-Monteith equation (PM-ETo) requires data on maximum and minimum air temperatures (Tmax, Tmin), relative humidity (RH), solar radiation (Rs), and wind speed (u2). However, the records of meteorological variables are often incomplete or of poor quality. Frequently, in the mountain areas such as those of the Andes, environmental sensors are subject to harsh conditions, due to the diurnal/nocturnal climatic variability causing challenging conditions for meteorological monitoring, which leads to data loss. For high-elevation landscapes like the Andes, the missing variables of vapor pressure deficit and solar radiation cause a high impact on PM-ETo calculation. To assess these limitations, several methods relying on maximum and minimum temperature to estimate the missing variables have been considered in the present investigation. Based on data from three automatic weather stations in the high Tropical Andes (humid páramo, 3298 – 3955 m a.s.l.), we found that the calibration and validation of methods were essential to estimate Rs. Using the (De Jong and Stewart, 1993) (Rs-DS) method we retrieved the highest performance, a RMSE between 2.89 and 3.81 MJ m−2 day−1. Moreover, In the absence of RH observations, replacing the dew point temperature (Tdew) by Tmin was a reliable alternative, when apply the method of (Allen et al., 1998) (VPD-FAO) which showed the highest performance with RMSE between 0.08 and 0.12 kPa. These results yielded highly accurate PM-ETo estimates, with RMSE between 0.29 and 0.34 mm day−1 and RMSE between 0.12 and 0.18 mm day−1, respectively. As expected, when both variables were missing, the ETo calculation increased its error, with an RMSE between 0.32 and 0.42 mm day−1. A proper estimation of ETo in the Andean páramo contributes to improved water productivity for domestic and industrial uses, irrigated agriculture, and hydropower.
URI : http://dspace.ucuenca.edu.ec/handle/123456789/40857
https://www.scopus.com/record/display.uri?eid=2-s2.0-85122469452&doi=10.1016%2fj.agwat.2021.107439&origin=inward&txGid=5c358660a80071886848c46e3f01d2b3
URI Fuente: https://www.sciencedirect.com/journal/agricultural-water-management/vol/262/suppl/C
ISSN : 0378-3774
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
documento.pdf2.3 MBAdobe PDFVisualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00