Logo Repositorio Institucional

Please use this identifier to cite or link to this item: https://dspace.ucuenca.edu.ec/handle/123456789/34334
Title: Pressure management for leakage reduction using pressure reducing valves. Case study in an Andean city
Authors: Ramos Fernández, Lia
Garcia Avila, Fausto Fernando
Aviles Añazco, Alex Manuel
Guanuchi Quezada, Christian Marcelo
Flores del Pino, Lisveth
metadata.dc.ucuenca.correspondencia: Garcia Avila, Fausto Fernando, fernando.garcia@ucuenca.edu.ec
Keywords: Performance indicators
Drinking water management
Hydraulic pipe modeling
Leakages
Water losses
WaterNetGen
Drinking water management
Hydraulic pipe modeling
Leakages
Performance indicators
Water losses
WaterNetGen
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.4.2 Ingeniería de Procesos Químicos
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.4 Ingeniería Química
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0711 - Ingeniería y Procesos Químicos
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2019
metadata.dc.ucuenca.volumen: Volumen 58, número 4
metadata.dc.source: Alexandria Engineering Journal
metadata.dc.identifier.doi: 10.1016/j.aej.2019.11.003
metadata.dc.type: ARTÍCULO
Abstract: 
A very common problem in distribution systems is water leakage, which can be reduced by pressure management. The objective of this study was to evaluate the reduction of water leakage by optimizing the pressure using pressure reducing valves (PRV). The corresponding hydraulic model of a real distribution network was developed using the EPANET software. After the hydraulic model was calibrated and validated, the analysis of the pressure in the nodes, the velocity in the pipes, through the technical performance indicators (TPI) was performed, in addition, the leakages were quantified. The initial results indicated the need to optimize the pressure, nodes with excessive pressures were found in the lower part of the network. WaterNetGen was used as an extension of EPANET software to model leakages based on pressure after determining the leakage coefficient and considering the installation of two PRVs. The results allowed optimizing the appropriate pressure in 30.83% of the nodes and minimizing leakages in 31.65%. In turn, the simulation assuming the installation of two PRVs determined that the TPI would increase from 79.81% to 97.45%. The focus of this study is recommended to the companies that supply drinking water as a support tool for planning to reduce leakages.
Description: 
A very common problem in distribution systems is water leakage, which can be reduced by pressure management. The objective of this study was to evaluate the reduction of water leakage by optimizing the pressure using pressure reducing valves (PRV). The corresponding hydraulic model of a real distribution network was developed using the EPANET software. After the hydraulic model was calibrated and validated, the analysis of the pressure in the nodes, the velocity in the pipes, through the technical performance indicators (TPI) was performed, in addition, the leakages were quantified. The initial results indicated the need to optimize the pressure, nodes with excessive pressures were found in the lower part of the network. WaterNetGen was used as an extension of EPANET software to model leakages based on pressure after determining the leakage coefficient and considering the installation of two PRVs. The results allowed optimizing the appropriate pressure in 30.83% of the nodes and minimizing leakages in 31.65%. In turn, the simulation assuming the installation of two PRVs determined that the TPI would increase from 79.81% to 97.45%. The focus of this study is recommended to the companies that supply drinking water as a support tool for planning to reduce leakages.
URI: http://dspace.ucuenca.edu.ec/handle/123456789/34334
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85076562608&origin=inward
metadata.dc.ucuenca.urifuente: https://www.sciencedirect.com/journal/alexandria-engineering-journal/vol/58/issue/4
ISSN: 1110-0168
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdfdocument4.78 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00