Logo Repositorio Institucional

Please use this identifier to cite or link to this item: https://dspace.ucuenca.edu.ec/handle/123456789/32409
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorMinchala Ávila, Luis Ismael-
dc.contributor.authorBlandín Segarra, Jonnathan Mauricio-
dc.contributor.authorVelasco Gordillo, Anthony Javier-
dc.date.accessioned2019-04-16T16:55:53Z-
dc.date.available2019-04-16T16:55:53Z-
dc.date.issued2019-04-16-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/32409-
dc.descriptionEl riesgo de lesionar el aparato locomotor es común debido a la actividad física a la que están sometidas las extremidades inferiores, ya sea en actividades cotidianas, de recreación o de competición. En este sentido, para prolongar la independencia motora del individuo dentro de una vida normal, las terapias de rehabilitación son primordiales en la mantención e incluso en la mejora de las capacidades motoras. Hoy en día, existe un gran número de investigaciones interesadas en solucionar y reducir estas limitaciones traumatológicas, bajo el fundamento científico y desarrollo de tecnología, logrando así, la exploración de prototipos robóticos para la asistencia y rehabilitación llamados exoesqueletos. El presente trabajo ofrece una alternativa a las terapias de rehabilitación basado en un sistema de instrumentación, control y comunicaciones de un exoesqueleto robótico para extremidades inferiores. El sistema de instrumentación se encarga de recolectar la información requerida a través de la red de comunicaciones formada por el protocolo CAN, para que el esquema de control PID tome decisiones en alusión a una trayectoria extraída de sujetos sin patologías. El diseño e implementación del dispositivo se aplica a la extremidad inferior izquierda y cuenta con tres grados de libertad correspondientes a las articulaciones de la cadera, rodilla y tobillo, las cuales se desplazan en el plano sagital. En esta primera versión se han ocupado cajas reductoras de tipo cicloidal y planetario para aumentar el torque en las articulaciones, siendo este primero de mayor relevancia por el aumento en el desempeño del control. Investigaciones futuras se enfocarán en la mejora de tasas de transmisión y tiempos de procesamiento.es_ES
dc.description.abstractThe risk of injury to the locomotor system is common due to the physical activity to which the lower extremities are subjected, whether in daily activities, recreation or competition. In this sense, to prolong the motor independence of the individual within a normal life, rehabilitation therapies are essentials in the maintenance and even in the improvement of motor skills. Nowadays, there are many researches interested in solving and reduce these traumatological limitations, under the scientific foundation and technology development, thus achieving the exploration of robotic prototypes for assistance and rehabilitation called exoskeletons. This research work offers an alternative to rehabilitation therapies based on a system of instrumentation, control and communications of a robotic exoskeleton for lower extremities. The instrumentation system is responsible for collecting the required information through the communications network formed by the CAN protocol, so that the PID control scheme makes decisions in reference to a trajectory extracted from subjects without pathologies. The design and implementation of the device is applied to the left lower extremity and it has three degrees of freedom corresponding to the joints of the hip, knee and ankle, which move in the sagittal plane. In this first version, gearboxes of cycloidal and planetary type have been occupied to increase the torque in the joints, the first being of greater relevance due to the increase in the performance of the control. Future research will focus on improving transmission rates and processing times.es_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.relation.ispartofseriesTET;80-
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectElectrónicaes_ES
dc.subjectSistemas de comunicaciónes_ES
dc.subjectTelecomunicacioneses_ES
dc.subjectSistemas de controles_ES
dc.subjectBiomecánicaes_ES
dc.titleDiseño e implementación del sistema de instrumentación y comunicaciones de un exoesqueleto de extremidades inferioreses_ES
dc.typebachelorThesises_ES
dc.ucuenca.paginacion116 páginases_ES
dc.description.degreeIngeniero en Electrónica y Telecomunicacioneses_ES
dc.contributor.assessorVázquez Rodas, Andrés Marcelo-
dc.description.cityCuenca, Ecuadores_ES
dc.ucuenca.id0301453486es_ES
dc.ucuenca.idautor0105099949es_ES
dc.ucuenca.idautor0302450051es_ES
dc.ucuenca.embargoend2021-02-15-
dc.ucuenca.versionsubmittedVersiones_ES
dc.ucuenca.correspondenciajomac23@live.comes_ES
dc.ucuenca.correspondenciatony.velascog@gmail.comes_ES
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
Trabajo-de-Titulación.pdfVersión presentada (texto completo)12.53 MBAdobe PDFView/Open


This item is protected by original copyright



This item is licensed under a Creative Commons License Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00