Título : Effect of the resolution of tipping-bucket rain gauge and calculation method on rainfall intensities in an andean mountain gradient
Autor: Muñoz, P
Celleri Alvear, Rolando Enrique
Feyen, Jan Jozef Albert
Correspondencia: Muñoz, P.; Departamento de Recursos Hídricos y Ciencias Ambientales, Universidad de CuencaEcuador; email: paul.andres.munoz@gmail.com
Palabras clave : Altitudinal Gradient
Ecuador
Percent Absolute Bias
Precipitation Sensor
Páramo Ecoregion
Rainfall Intensity
Fecha de publicación : 16-nov-2016
Fecha de fin de embargo: 1-ene-2022
Volumen: 8
Fuente: Water (Switzerland)
metadata.dc.identifier.doi: 10.3390/w8110534
Editor: MDPI AG
Tipo: Article
Abstract: 
A laser-optical disdrometer served as reference to assess the absolute percent bias of calculated rainfall intensity using the data of different-resolution tipping-bucket rain gauges classically applied by climatologists and hydrologists in the Andean region. Additionally, the impact of the calculation method (tip counting versus cubic spline interpolation) was examined. The combined effect was assessed for different rainfall intensity classes (0-0.99, 1-1.99, 2-4.99, and 5-10 mm·h-1) and timescales (5, 10, 30, and 60 min). Additionally, the variation in percent absolute bias of the Davis rain gauge, the collector most widely used in the study region, was defined with respect to the Texas rain gauge along an elevation gradient between 3300 and 4000 m a.s.l. Results reveal that the value of the percent absolute bias is largest for small rainfall intensities (?2 mm·h-1) and short timescales (?10 min), and decreases when the cubic spline interpolation is used. No relation was found between the error, the elevation, and rainfall depth along the gradient. Based on the research findings, it is recommended to measure precipitation in the high Andean mountain region with a high-resolution sensor and to consider cubic spline for the computation of intensities.
URI : https://www.scopus.com/inward/record.uri?eid=2-s2.0-85003502834&doi=10.3390%2fw8110534&partnerID=40&md5=a948549a5e832026b0a6f196e8b5d299
http://dspace.ucuenca.edu.ec/handle/123456789/28971
ISSN : 20734441
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
documento.pdf168.92 kBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00